Description of the data path
PIKE Technical Manual V4.0.0
122
To configure auto gain control in an advanced register: See Table 150:
Advanced register for auto gain control on page 300.
Register Name Field Bit Description
0xF0F00804 AUTO_EXPOSURE Presence_Inq [0] Presence of this feature:
0: N/A
1: Available
Abs_Control [1] Absolute value control
O: Control with value in the value field
1: Control with value in the absolute
value CSR
If this bit=1 the value in the value field
has to be ignored.
- [2..4] Reserved
One_Push [5] Write: Set bit high to star
Read: Status of the feature:
Bit high: WIP
Bit low: Ready
ON_OFF [6] Write: ON or OFF this feature
Read: read a status
0: OFF
1: ON
A_M_MODE [7] Write: set mode
Read: read current mode
0: MANUAL
1: AUTO
- [8..19] Reserved
Value [20..31] Read/Write Value
This field is ignored when writing the
value in Auto or OFF mode.
If readout capability is not available,
reading this field has no meaning.
Table 50: Auto Exposure CSR
Note
L
Values can only be changed within the limits of gain
CSR.
Changes in auto exposure register only have an effect
when auto gain is active.
Auto exposure limits are 50..205. (SmartViewCtrl1
tab: Target grey level)