Controlling image capture
PIKE Technical Manual V4.0.0
188
In this case the camera can resynchronize the horizontal clock to the new
trigger event, leaving only a very short uncertainty time of the master clock
period.
Model Exposure start jitter
(while FVal)
Exposure start jitter
(while camera idle)
Pike F-032 ± 4.9 µs ± 375 ns
Pike F-100 ± 8.2 µs ± 1.65 µs
Pike F-145 ± 16 µs ± 2.9 µs
Pike F-145-15fps ± 30 µs ± 5.4 µs
Pike F-210 ± 14.25 µs ± 1.8 µs
Pike F-421 ± 15 µs ± 1.65 µs
Pike F-505 ± 17 µs ± 5.7 µs
Table 77: Jitter at exposure start (no binning, no sub-sampling)
Note
L
• Jitter at the beginning of an exposure has no effect on
the length of exposure, i.e. it is always constant.
Comentarios a estos manuales