Configuration of the camera
PIKE Technical Manual V4.0.0
312
Secure image signature (SIS)
Secure image signature (SIS) is the synonym for data, which is inserted into
an image to improve or check image integrity.
All PIKE models can insert
Time stamp (1394 bus cycle time at the beginning of integration)
Frame counter (frames read out of the sensor)
Trigger counter (external trigger seen only)
Various camera settings
into a selectable line position within the image. Frame counter and trigger
counter are available as advanced registers to be read out directly.
Advanced register: SIS
The SIS feature is controlled by the following advanced feature register:
Enabling this feature, SIS data will be inserted into any captured image. The
size of SIS data depends on the selected SIS format.
The LineNo field indicates at which line the SIS data will be inserted.
Note
L
This register is different to the MARLIN Timestamp (600)
register!
Register Name Field Bit Description
0xF1000630 SIS Presence_Inq [0] Indicates presence of this
feature (read only)
--- [1..5] Reserved
ON_OFF [6] SIS mode on/off
--- [7.. 15] Reserved
LineNo [16..31] SIS data position inside an
image
0xF1000634 UserValue [0..31] User provided value for
sequence mode to be placed
into the SIS area of an image
Table 162: Advanced register: SIS