Bulk Trigger (Trigger_Mode_15)
Trigger_Mode_15 is an extension to the IIDC trigger modes. One external
trigger event can be used to trigger a multitude of internal image intakes.
This is especially useful for:
Grabbing exactly one image based on the first external trigger.
Filling the camera's internal image buffer with one external trigger with-
out overriding images.
Grabbing an unlimited amount of images after one external trigger (sur-
veillance)
The Figure below illustrates this mode.
The functionality is controlled via bit [6] and bitgroup [12-15] of the follow-
ing register:
Figure 93: Trigger_Mode_15
External Trigger input, after inverting optocoupler
N x image; N: continuous, one_shot, multi_shot