Allied Vision Technologies AVT Stingray Manual de instrucciones Pagina 166

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 309
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 165
Controlling image capture
STINGRAY Technical Manual V2.2.0
165
The lowest possible value of ExpTime is camera-specific (see Table 60: Cam-
era-specific minimum exposure time on page 165).
Note
L
Exposure times entered via the 81Ch register are mir-
rored in the extended register, but not vice versa.
Longer integration times not only increase sensitivity,
but may also increase some unwanted effects such as
noise and pixel-to-pixel non-uniformity. Depending on
the application, these effects may limit the longest
usable integration time.
Changes in this register have immediate effect, even
when the camera is transmitting.
Extended shutter becomes inactive after writing to a
format/mode/frame rate register.
Vista de pagina 165
1 2 ... 161 162 163 164 165 166 167 168 169 170 171 ... 308 309

Comentarios a estos manuales

Sin comentarios