Allied Vision Technologies AVT Stingray Manual de instrucciones Pagina 175

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 309
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 174
Controlling image capture
STINGRAY Technical Manual V2.2.0
174
Enabling this feature turns the camera into a special mode. This mode can be
used to set up a bunch of parameter sets for up to MaxLength consecutive
images.
Setup mode
The SetupMode flag allows you to set up a sequence while capturing images.
Using this flag you get a visual feedback of the settings.
Set SetupMode flag when setting up the sequence and reset the flag before
using the sequence.
Sequence step mode
The SeqMode field selects the signal source for stepping the sequence one
parameter set further.
0xF1000228 SEQUENCE_STEP Presence_Inq [0] Indicates presence of this feature
(read only)
--- [1..4] Reserved
PerformStep [5] Sequence is stepped one item for-
ward
PerformReset [6] Sequence reset
--- [7..23] Reserved
SeqPosition [24..31] Get the current sequence position
0xF100022C SEQUENCE_RESET Presence_Inq [0] Indicates presence of this feature
(read only)
--- [1..4] Reserved
PerformReset [5] Reset the sequence to start position
--- [6..31] Reserved
Note
L
The sequence mode of the Stingray series behaves slightly
different than the sequence mode of e.g. the Marlin series
and implements some new controlling features. You may use
a sequence with internal or external trigger and with the
Deferred Transport feature.
Register Name Field Bit Description
Table 67: Advanced register: Sequence mode
Vista de pagina 174