Controlling image capture
STINGRAY Technical Manual V2.2.0
176
The following flow diagram shows how to set up a sequence.
During sequencing, the camera obtains the required parameters, image by
image, from the corresponding FIFOs (e.g. information for exposure time).
Figure 96: Sequence mode flow diagram
Set
SEQUENCE_CTRL
ON_OFF flag to
true (1)
Set
SetupMode to
true (1)
Set SeqLength to
desired length
(<=MaxLength)
Set ImageNo = 0 in
SEQUENCE_PARAM
Assign image
parameters in the
corresp. registers
Increment
ImageNo
Repeat steps until
sequence is
complete
Start sequence in
MultiShot or
ISOEnable mode
ApplyParameters
= 1 (Selfcleared)
Disable SetupMode